HSD-Sequencer V700-EM
The HSD-Sequencer V700-EM is an EURO module developed for creating complex patterns of pulses (sequences) on multiple outputs. The pulse width, the time interval between pulses, the number of pulses and the output channel number are software programmable. The Sequencer has 16 pulse outputs, Arming inputs, Trigger inputs and External clock input. There is also onboard generator which can be used independently. The Sequencer can work in one of the five Working Modes. The users can define many of pulse sequences which are generated on the outputs depending on Working Mode. Arming and Trigger inputs are used for starting sequences. Additional inputs and outputs can be used to control other equipment in the system.
The HSD-Sequencer V700-EM can be used for triggering of complex scientifical and industrial set-ups applying various components such as multi-camera systems, pulsed light sources and accompanying devices. It is particularly useful in machine automation and electronic testing.

The HSD-SequencerV700-EM in the standard-version has connector 160 pins. The new standard makes possible the use LVDS outputs and TTL outputs.

Due to their flexibility, sequencers can be integrated into several demanding scientific systems (e.g., PIV) for triggering and synchronizing of their components.


Parameters:
Sixteen outputs: TTL standard, (LVDS standard - option),
Five working modes: Single, Restart, Continue, Trickle, Arming-Continue
Inputs: Arming1 TTL standard,
Arming2 LVDS standard,
Arming3 TTL standard,
Software simulated Arming functon
Programmable active slope of Arming pulses
Inputs: Trigger1 TTL standard,
Trigger2 LVDS standard,
Trigger3 Analog with programmable Lowpass Filter,
Trigger4 TTL standard with iCoupler Digital Isolator,
Trigger5 TTL standard
Internal input Trigger with programmable frequency
Software simulated Trigger functon
Programmable active slope of Trigger pulses
Minimum delay 5 ns
Maximum delay 20 s
Minimum pulse width 5 ns
Maxmum pulse width 20 s
Resolution 5 ns
Up to 100 Sequences
Up to 1000 events
Input to output jitter: 1,25 ns
Two channels DAC, resolution 8 bit, 0-5V
One additional 8 bit output ports
Four opto-coupler logic inputs

Configuration software works under Windows 98/2000/NT/XP. The Sequencer can be programmed by means of the sequencer software via the RS-232 serial port.

 

 

Select from list:
Phase Shifter / Time Delayer CPFT V4.1
HS-PSTD-V500
HSC-40BW Camera
HSC-145S Camera
HSC-55BW Camera
HSD-NCO V200
HSD-MUX-V10-PD
Sequencer V5.0 EURO
Sequencer V5.11
Sequencer V801-BM
HSD-Sequencer V700-EM
HSD-Sequencer V710-EM
HSD-Sequencer V720-EM
HSD-Sequencer V750-EM
IL-105/6X Illuminator
 
 
  © lmd.pl
high speed video systems data acquistion industrial controllers