home | company | products | application | contact us polski | english
HSCamS-8145 Multi-camera System
HSCamS-8145 Multi-camera System
The HSCamS-8145 camera system consists of eight cameras HSC-145BW and the Control Unit. The system can control additional light sources for example special flash-lamps. The system is connected to the computer via PCI card, HSD-IO-211.
All parameters of the system are controlled through the software installed in the computer. All cameras are connected to the Control Unit via LVDS cables and the Control Unit is connected to the computer also via LVDS cable. The LVDS standard used in the camera system makes possible to increase the distance between cameras and the computer.

The camera system can record the series of eight frames with the very high speed: 1000000 fps.

Parameters
Sensor 2/3" Progressive Scan, black and white
Resolution 1360(H) x 1024(V)
Pixel 6,45µm x6,45µm
Digitizer Video 10Bit/20MHz
Asynchronic shutter 1µs do 100ms
Interframe time 0ns to 1s, step 50ns
Jitter 12,5ns
External Trigger TTL
Lens mount C-mount

Very short exposure period (1us) and asynchronous work mode make it possible to apply the camera for registering very fast phenomena in a selected time moment. The camera can be additionally equipped with the image intensifier (MCP) which shortens the shutter time up to 30ns (10ns).


 
The Control Unit is central part of the system. It controls all cameras and light sources. It also enables to communicate with PC and installed software.
The Control Unit includes the following elements:
  • Sequencer V5.11-Euro module,
  • eight HSD-CAMINT-V25 modules camera interface,
  • HSD-PCINT-V25 module - PC interface.

All modules are installed in the 19" case.
Sequencer V5.11-Euro is programmable, 16 channels pulse generator. Eight channels controls light sources, and next eight channels controls cameras. The exposure time shutter is defined by pulse duration.


Software
The software features:
  • controls all parameters of the system,
  • transfers images,
  • records images to hard disk,
  • simple operations on images: profile and histogram.
HSCamS-8145 system configuration covers the following areas:
  • camera parameters,
  • exposure times for each of camera,
  • delays between cameras and light sources signals,
  • runtime mode : Live, Triggered, Single, Automatic.

 

Select from list:
HSCamS-Vstroboscope
PIV Systems
HSCamS-145PIV PIV System
HSSeqS-V10M PIV System
HSCamS-3145TMI
HSCamS-6145
HSCamS-8145
Cordin Model 220-8
 
  © lmd.pl
high speed video systems data acquistion industrial controllers